1.
Ear Hear ; 36(2): 249-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25259669

RESUMO

OBJECTIVES: The goal was to measure the magnitude of cochlear responses to sound in pediatric cochlear implant recipients at the time of implantation and to correlate this magnitude with subsequent speech perception outcomes. DESIGN: A longitudinal cohort study of pediatric cochlear implant recipients was undertaken. Intraoperative electrocochleographic (ECoG) recordings were obtained from the round window in response to a frequency series at 90 dB nHL in 77 children totaling 89 ears (12 were second side surgeries) just before device insertion. The increase in intraoperative time was approximately 10 min. An ECoG "total response" metric was derived from the summed magnitudes of significant responses to the first, second, and third harmonics across a series of frequencies. A subset of these children reached at least 9 months of implant use and were old enough for the phonetically balanced kindergarten (PB-k) word test to be administered (n = 26 subjects and 28 ears). PB-k scores were compared to the ECoG total response and other biologic and audiologic variables using univariate and multiple linear regression analyses. RESULTS: ECoG responses were measurable in almost all ears (87 of 89). The range of ECoG total response covered about 60 dB (from ~0.05 to 50 µV). Analyzing individual ECoG recordings in bilaterally implanted children revealed poor concordance between the measured response in the first versus second ear implanted (r = 0.21; p = 0.13; n = 12). In a univariate linear regression, the ECoG total response was significantly correlated with PB-k scores in the subset of 26 subjects who were able to be tested and accounted for 32% of the variance (p = 0.002, n = 28). Preoperative pure-tone average (PTA) accounted for slightly more of the variance (r = 0.37, p = 0.001). However, ECoG total response and PTA were significantly but only weakly correlated (r = 0.14, p = 0.001). Other significant predictors of speech performance included hearing stability (stable versus progressive) and age at testing (22 and 16% of the variance, respectively). In multivariate analyses with these four factors, the ECoG accounted for the most weight (ß = 0.36), followed by PTA (ß = 0.26). In a hierarchical multiple regression analysis, the most parsimonious models that best predicted speech perception outcomes included three variables: ECoG total response, and any two of preoperative PTA, age at testing, or hearing stability. The various three factor models each predicted approximately 50% of the variance in word scores. Without the ECoG total response, the other three factors predicted 36% of variance. CONCLUSIONS: Intraoperative round window ECoG recordings are reliably and easily obtained in pediatric cochlear implant recipients. The ECoG total response is significantly correlated with speech perception outcomes in pediatric implant recipients and can account for a comparable or greater proportion of variance in speech perception than other bio-audiologic factors. Intraoperative recordings can potentially provide useful prognostic information about acquisition of open set speech perception in implanted children.


Assuntos
Perda Auditiva/reabilitação , Janela da Cóclea/fisiopatologia , Percepção da Fala , Adolescente , Audiometria de Resposta Evocada , Criança , Pré-Escolar , Implante Coclear/métodos , Estudos de Coortes , Feminino , Perda Auditiva/fisiopatologia , Humanos , Lactente , Cuidados Intraoperatórios , Modelos Lineares , Estudos Longitudinais , Masculino , Análise Multivariada , Prognóstico , Estudos Prospectivos , Resultado do Tratamento
2.
Otol Neurotol ; 36(4): 670-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25280052

RESUMO

HYPOTHESIS: Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. BACKGROUND: Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. METHODS: The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 µm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. RESULTS: Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. CONCLUSION: Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.


Assuntos
Implante Auditivo de Tronco Encefálico , Nervo Coclear/cirurgia , Núcleo Coclear/patologia , Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Traumatismos do Nervo Vestibulococlear/complicações , Animais , Implante Auditivo de Tronco Encefálico/efeitos adversos , Implante Auditivo de Tronco Encefálico/métodos , Implantes Auditivos de Tronco Encefálico , Nervo Coclear/lesões , Modelos Animais de Doenças , Gerbillinae , Masculino
3.
Otol Neurotol ; 35(9): e245-52, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25118584

RESUMO

HYPOTHESIS: Intraoperative round window (RW) electrocochleography (ECoG) can help predict speech perception outcomes in adult cochlear implant (CI) recipients. BACKGROUND: Speech perception outcomes using CIs are highly variable. Recent data demonstrated that intraoperative ECoG could account for nearly half the variance in postoperative word scores. The present study seeks to update this correlation with a larger sample size and determine if addition of clinical variables improves the prediction. METHODS: Intraoperative RW ECoG was performed in adult subjects undergoing CI. Amplitudes of the ongoing response to tone bursts of multiple frequencies at 85 to 95 dB HL were summed to obtain the total response (ECoG-TR). ECoG-TR was correlated with postoperative speech perception scores. Multiple linear regression was used to combine clinical factors with the ECoG-TR. RESULTS: The ECoG-TR accounted for 40% of the variance in CNC word scores (n = 32). The preoperative pure tone average (PTA) was the only clinical factor with a significant correlation (r² = 20%). The ability to predict word scores using ECoG-TR and PTA, or after addition of age and duration of hearing loss, was not significantly different from using ECoG-TR alone. For 2 outliers, ECoG-TR predicted a better word score than obtained. CONCLUSIONS: The measurement of cochlear physiology before CI, reduced to a single variable, is a better predictor of postoperative speech perception than common clinical factors. Additional analysis of the outliers showed that waveform morphology can provide distinct information in individual cases.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Monitorização Neurofisiológica Intraoperatória/métodos , Janela da Cóclea/fisiopatologia , Percepção da Fala/fisiologia , Adulto , Idoso , Audiometria , Audiometria de Resposta Evocada , Surdez/cirurgia , Eletrofisiologia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Janela da Cóclea/cirurgia